Flyback Transformer Primary Inductance & Peak Current Calculator

Flyback converters store energy in the transformer core air gap during the primary MOSFET ON-time and release it to the secondary output during the OFF-time.

Minimum rectified DC input rail voltage under worst-case brownout.

Total electrical load power delivered by all secondary windings.

PWM switching frequency of the flyback controller.

Maximum operating duty cycle allowed at minimum input voltage.

Estimated converter power conversion efficiency.

Calculated Result
143.4 µH

Primary Inductance (Lp)

Peak Switch Current Ipk

3.14 A

RMS Switch Current Irms

1.22 A

Input Power Pin

70.6 W

Operating Mode

DCM Boundary (Discontinuous)

Calculation Breakdown

  1. Input Power & DCM Energy SizingP_in = P_out / η = 60 / 0.85 = 70.6 W
  2. Primary Magnetizing Inductance (Lp)L_p = (V_in,min² · D_max²) / (2 · P_in · f_sw) = (100² · 0.45²) / (2 · 70.6 · 100000) = 143.4 µH
  3. Peak & RMS Primary Switch CurrentsI_pk = (2 · P_in) / (V_in,min · D_max) = 3.14 A; I_rms = I_pk · √(D_max / 3) = 1.22 A

Flyback Transformer Design Values

Interactive visualization based on your current inputs

Value
0.03672107143Primary Lp (µH)Peak Ipk (A)RMS Irms (A)Input Power (W)ParameterValue

What Is the Flyback Transformer Primary Inductance & Peak Current Calculator?

Flyback converters store energy in the transformer core air gap during the primary MOSFET ON-time and release it to the secondary output during the OFF-time.

Selecting the correct primary magnetizing inductance Lp ensures complete core energy discharge in Discontinuous Conduction Mode (DCM) without exceeding switch current limits.

This calculator computes primary inductance Lp, peak primary current Ipk, RMS primary current, and input power demand.

How Does the Flyback Transformer Primary Inductance & Peak Current Calculator Work?

The calculation evaluates user-provided measurements using recognized domain equations, converts between measurement units, and adjusts for real-world efficiency factors.

Flyback Transformer Primary Inductance & Peak Current Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

Lp = (Vin,min² · Dmax²) / (2 · Pin · fsw), Ipk = (2 · Pin) / (Vin,min · Dmax)

Volt-second energy conservation formulation defining primary magnetizing inductance at DCM boundary.

How to Use the Flyback Transformer Primary Inductance & Peak Current Calculator

  1. Enter your primary measurements in the input fields above.
  2. Select your preferred units (e.g. metric or imperial) if applicable.
  3. Review or adjust operational assumptions such as field efficiency.
  4. Click Calculate to instantly generate the full results breakdown and visual chart.
  5. Use the Reset button at any time to clear the form and test a new scenario.

Step-by-Step Example Calculation

Universal Mains SMPS (Vin,min = 100V, Pout = 60W, fsw = 100 kHz, Dmax = 0.45)

Input Values:

minimumInputVoltageV:100
outputPowerWatts:60
switchingFrequencyKhz:100
maximumDutyCycleDmax:0.45
targetEfficiencyPercent:85
Worked Steps: Requires primary inductance Lp = 143.2 µH, with peak switch current Ipk = 3.14 A and Irms = 1.22 A.

Understanding Your Result

Your calculated result represents the realistic operational capacity or baseline output under the specified conditions. Comparing theoretical and effective outputs reveals the direct impact of turns, overlap, and practical downtime.

Factors That Affect the Result

Field terrain, operator experience, equipment maintenance, overlap margin, and weather conditions can significantly influence real-world output.

When Should You Use This Calculator?

Use this calculator whenever you need quick, verified estimates for job planning, budgeting, equipment sizing, or project timelines.

Assumptions & Limitations

  • Flyback transformers actually function as coupled inductors because they store energy in the magnetic air gap rather than transferring power directly.
  • A lower primary inductance increases peak switch currents and conduction losses, while excessively high inductance forces Continuous Conduction Mode (CCM).