Differential Orifice Plate Flow Meter Mass Flow Calculator (ISO 5167)

Orifice meters are the most widely used differential pressure flow measurement instruments in the energy and oil & gas sectors.

Internal pipe bore diameter

Inside orifice throat bore diameter

Differential pressure across flange taps

Process fluid operating density

Calculated Result
2.121 kg/s

Measured Mass Flow Rate

Diameter Ratio (β = d/D)

0.5

Calculation Breakdown

  1. ISO 5167 Orifice Meter Formulationqm = [Cd / √(1 - β⁴)] · A2 · √(2ρΔP) => 2.121 kg/s

Flow vs Differential Pressure

Interactive visualization based on your current inputs

qm
0.01.22.43.64.810 kPa25 kPa50 kPaΔP (kPa)Mass Flow (kg/s)

What Is the Differential Orifice Plate Flow Meter Mass Flow Calculator (ISO 5167)?

Orifice meters are the most widely used differential pressure flow measurement instruments in the energy and oil & gas sectors.

ISO 5167 standardizes discharge coefficients (Cd) and velocity-of-approach factors to ensure fiscal accuracy.

How Does the Differential Orifice Plate Flow Meter Mass Flow Calculator (ISO 5167) Work?

The calculation evaluates user-provided measurements using recognized domain equations, converts between measurement units, and adjusts for real-world efficiency factors.

Differential Orifice Plate Flow Meter Mass Flow Calculator (ISO 5167) Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

q_m = \frac{C_d}{\sqrt{1 - \beta^4}} \frac{\pi d^2}{4} \sqrt{2 \rho \Delta P}

ISO 5167 differential pressure mass flow equation.

How to Use the Differential Orifice Plate Flow Meter Mass Flow Calculator (ISO 5167)

  1. Enter your primary measurements in the input fields above.
  2. Select your preferred units (e.g. metric or imperial) if applicable.
  3. Review or adjust operational assumptions such as field efficiency.
  4. Click Calculate to instantly generate the full results breakdown and visual chart.
  5. Use the Reset button at any time to clear the form and test a new scenario.

Step-by-Step Example Calculation

Pipeline Natural Gas Meter Run

Input Values:

pipeInternalDiameterMm:200.0
orificeDiameterMm:110.0
differentialPressureKpa:35.0
gasDensityKgPerM3:22.0

Understanding Your Result

Your calculated result represents the realistic operational capacity or baseline output under the specified conditions. Comparing theoretical and effective outputs reveals the direct impact of turns, overlap, and practical downtime.

Factors That Affect the Result

Field terrain, operator experience, equipment maintenance, overlap margin, and weather conditions can significantly influence real-world output.

When Should You Use This Calculator?

Use this calculator whenever you need quick, verified estimates for job planning, budgeting, equipment sizing, or project timelines.

Assumptions & Limitations

  • Diameter ratio β = d / D must remain strictly between 0.10 and 0.75.