Skip to main content

Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator

Easily calculate and compute cryogenic tank boil-off rate (bor) & heat leak calculator with accurate equations, live formulas, and expert guidance.

Heat ingress through insulation and supports.

Total mass of stored cryogen.

LN2 = 199.1, LNG ~ 510, LH2 = 445.6 kJ/kg.

Calculated Result
0.65 %/day

Daily Boil-Off Rate (BOR)

Daily Boil-Off Rate (BOR)

0.65 %/day

Bor Percent Per Day

0.6509291813159217

Daily Boil Off Kg

781.1150175791059

Boil Off Kg Per Hour

32.54645906579608

0.65 — %/day

Calculation Breakdown

  1. Applied FormulaCalculates the daily percentage mass loss (Boil-Off Rate) of LNG, liquid hydrogen (LH2), or liquid nitrogen (LN2) storage tanks caused by ambient heat ingress.\text{BOR} = \frac{\dot{Q}_{\text{leak}} \cdot 86400}{M_{\text{liquid}} h_{fg}} \times 100\%

Cryogenic Boil-Off Rate Metric Output

Interactive visualization based on your current inputs

Calculated Value
0.00.30.50.81.0Daily Boil-Off Rate (BOR)

What Is the Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator?

This tool computes cryogenic tank boil-off rate (bor) & heat leak calculator with high precision arithmetic.

How Does the Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator Work?

Calculates the daily percentage mass loss (Boil-Off Rate) of LNG, liquid hydrogen (LH2), or liquid nitrogen (LN2) storage tanks caused by ambient heat ingress.

Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

BOR=Q˙leak⋅86400Mliquidhfg×100%\text{BOR} = \frac{\dot{Q}_{\text{leak}} \cdot 86400}{M_{\text{liquid}} h_{fg}} \times 100\%

Calculates the daily percentage mass loss (Boil-Off Rate) of LNG, liquid hydrogen (LH2), or liquid nitrogen (LN2) storage tanks caused by ambient heat ingress.

How to Use the Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator

  1. Enter your parameters into the designated input fields to calculate the result immediately.

Step-by-Step Example Calculation

Cryogenic Tank Boil-Off Rate (BOR) & Heat Leak Calculator Example

Input Values:

heatLeakWatts:1800
liquidMassTons:120
latentHeatKjPerKg:199.1
Worked Steps: Sample evaluation based on standard reference conditions.

Understanding Your Result

The calculated primary figure indicates the optimal or required %/day.

Factors That Affect the Result

  • Measurement tolerances, operational variance, and real-world conditions.

When Should You Use This Calculator?

  • Everyday budgeting, technical homework, professional estimation, and household projects.

Assumptions & Limitations

  • Assumes standard atmospheric or environmental parameters unless specified.

Frequently Asked Questions

Calculation Accuracy & Reference Note

Double-precision IEEE 754 arithmetic with validated empirical constants.

\n

Explore more tools and calculators in Physics Calculators