Skip to main content

Dielectrophoresis (DEP) & Clausius-Mossotti Calculator

Easily calculate and compute dielectrophoresis (dep) & clausius-mossotti calculator with accurate equations, live formulas, and expert guidance.

Particle/cell effective electrical conductivity.

Suspending buffer electrical conductivity.

Dielectric constant of cell.

Dielectric constant of liquid.

Frequency of applied micro-electrode voltage.

Calculated Result
0.5 factor

Real Part of Clausius-Mossotti Factor Re[f_CM]

Real Part of Clausius-Mossotti Factor Re[f_CM]

0.5 factor

Re Clausius Mossotti

0.49852660972049984

Is Positive Dep

1

Low Freq Limit

0.5

High Freq Limit

-0.0848708487084871

0.5 — factor

Calculation Breakdown

  1. Applied FormulaCalculates the complex Clausius-Mossotti polarization factor, crossover frequency, and positive/negative dielectrophoretic (pDEP/nDEP) forces for microfluidic cell sorting.f_{CM} = \frac{\varepsilon_p^* - \varepsilon_m^*}{\varepsilon_p^* + 2 \varepsilon_m^*}, \quad F_{DEP} = 2 \pi \varepsilon_m r^3 \text{Re}[f_{CM}] \nabla |E|^2

DEP Clausius-Mossotti Metric Output

Interactive visualization based on your current inputs

Calculated Value
0.00.30.50.81.0Real Part of Clausius-Mossotti Factor Re[f_CM]

What Is the Dielectrophoresis (DEP) & Clausius-Mossotti Calculator?

This tool computes dielectrophoresis (dep) & clausius-mossotti calculator with high precision arithmetic.

How Does the Dielectrophoresis (DEP) & Clausius-Mossotti Calculator Work?

Calculates the complex Clausius-Mossotti polarization factor, crossover frequency, and positive/negative dielectrophoretic (pDEP/nDEP) forces for microfluidic cell sorting.

Dielectrophoresis (DEP) & Clausius-Mossotti Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

fCM=εp∗−εm∗εp∗+2εm∗,FDEP=2πεmr3Re[fCM]∇∣E∣2f_{CM} = \frac{\varepsilon_p^* - \varepsilon_m^*}{\varepsilon_p^* + 2 \varepsilon_m^*}, \quad F_{DEP} = 2 \pi \varepsilon_m r^3 \text{Re}[f_{CM}] \nabla |E|^2

Calculates the complex Clausius-Mossotti polarization factor, crossover frequency, and positive/negative dielectrophoretic (pDEP/nDEP) forces for microfluidic cell sorting.

How to Use the Dielectrophoresis (DEP) & Clausius-Mossotti Calculator

  1. Enter your parameters into the designated input fields to calculate the result immediately.

Step-by-Step Example Calculation

Dielectrophoresis (DEP) & Clausius-Mossotti Calculator Example

Input Values:

cellConductivitySTurnover:0.04
mediumConductivitySTurnover:0.01
cellRelativePermittivity:60
mediumRelativePermittivity:78.4
acFrequencyKHz:250
Worked Steps: Sample evaluation based on standard reference conditions.

Understanding Your Result

The calculated primary figure indicates the optimal or required factor.

Factors That Affect the Result

  • Measurement tolerances, operational variance, and real-world conditions.

When Should You Use This Calculator?

  • Everyday budgeting, technical homework, professional estimation, and household projects.

Assumptions & Limitations

  • Assumes standard atmospheric or environmental parameters unless specified.

Frequently Asked Questions

Calculation Accuracy & Reference Note

Double-precision IEEE 754 arithmetic with validated empirical constants.

\n

Explore more tools and calculators in Physics Calculators