Skip to main content

Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator

Easily calculate and compute ginzburg-landau parameter (kappa) & critical fields (hc1, hc2) calculator with accurate equations, live formulas, and expert guidance.

Calculated Result
100 dim

Ginzburg-Landau Parameter (kappa)

Ginzburg-Landau Parameter (kappa)

100 dim

Ginzburg Landau Parameter Kappa

100

Superconductor Type Classification

TYPE-II SUPERCONDUCTOR (Abrikosov Vortex Mixed State Possible)

Upper Critical Field Bc2 Tesla

146.3

Lower Critical Field Bc1 Tesla

0.034

100 — dim

Calculation Breakdown

  1. Applied FormulaClassifies superconductors into Type-I or Type-II based on the Ginzburg-Landau parameter kappa (ratio of penetration depth to coherence length) and computes upper/lower critical fields.\kappa = \frac{\lambda_L}{\xi}, \quad B_{c2} = \sqrt{2} \kappa B_c = \frac{\Phi_0}{2\pi \xi^2}, \quad B_{c1} \approx \frac{\Phi_0}{4\pi \lambda_L^2} \ln\kappa

Ginzburg-Landau Kappa & Fields Metric Output

Interactive visualization based on your current inputs

Calculated Value
0.0255075100Ginzburg-Landau Parameter (kappa)

What Is the Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator?

The Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator computes results using established domain formulas, verified conversion factors, and user-entered parameters.

How Does the Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator Work?

Classifies superconductors into Type-I or Type-II based on the Ginzburg-Landau parameter kappa (ratio of penetration depth to coherence length) and computes upper/lower critical fields.

Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

\kappa = \frac{\lambda_L}{\xi}, \quad B_{c2} = \sqrt{2} \kappa B_c = \frac{\Phi_0}{2\pi \xi^2}, \quad B_{c1} \approx \frac{\Phi_0}{4\pi \lambda_L^2} \ln\kappa

Classifies superconductors into Type-I or Type-II based on the Ginzburg-Landau parameter kappa (ratio of penetration depth to coherence length) and computes upper/lower critical fields.

How to Use the Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator

  1. Enter your parameters into the designated input fields to calculate the result immediately.

Step-by-Step Example Calculation

Ginzburg-Landau Parameter (kappa) & Critical Fields (Hc1, Hc2) Calculator Example

Input Values:

penetrationDepthNm:150
coherenceLengthNm:1.5
Worked Steps: Sample evaluation based on standard reference conditions.

Understanding Your Result

The calculated primary figure indicates the optimal or required dim.

Factors That Affect the Result

  • Measurement tolerances, operational variance, and real-world conditions.

When Should You Use This Calculator?

  • Everyday budgeting, technical homework, professional estimation, and household projects.

Assumptions & Limitations

  • Assumes standard atmospheric or environmental parameters unless specified.

Frequently Asked Questions

Calculation Accuracy & Reference Note

Double-precision IEEE 754 arithmetic with validated empirical constants.

\n

Explore more tools and calculators in Physics Calculators