Skip to main content

Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator

Easily calculate and compute meyerhof foundation bearing capacity with load inclination & eccentricity calculator with accurate equations, live formulas, and expert guidance.

Physical foundation width.

Physical foundation length.

Offset distance of load from centroid (e_B < B/6 to avoid tension).

Angle of resultant load vector relative to vertical.

Foundation depth.

Internal friction angle.

Soil unit weight.

Calculated Result
416.4 kPa

Meyerhof Capacity (q_ult)

Meyerhof Capacity (q_ult)

416.4 kPa

Meyerhof Ultimate Capacity Kpa

416.4

Effective Footing Width B Prime M

2.1

Effective Footing Area M2

7.35

Load Inclination Factor Iq

0.751

416.4 — kPa

Calculation Breakdown

  1. Applied FormulaCalculates the reduced bearing capacity of shallow foundations subjected to inclined horizontal shear forces and eccentric bending moments using Meyerhof effective width (B') theory.q_u = c N_c s_c d_c i_c + q N_q s_q d_q i_q + \frac{1}{2}\gamma B' N_\gamma s_\gamma d_\gamma i_\gamma

Meyerhof Bearing Capacity Metric Output

Interactive visualization based on your current inputs

Calculated Value
0.0104208312416Meyerhof Capacity (q_ult)

What Is the Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator?

This tool computes meyerhof foundation bearing capacity with load inclination & eccentricity calculator with high precision arithmetic.

How Does the Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator Work?

Calculates the reduced bearing capacity of shallow foundations subjected to inclined horizontal shear forces and eccentric bending moments using Meyerhof effective width (B') theory.

Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

qu=cNcscdcic+qNqsqdqiq+12γB′Nγsγdγiγq_u = c N_c s_c d_c i_c + q N_q s_q d_q i_q + \frac{1}{2}\gamma B' N_\gamma s_\gamma d_\gamma i_\gamma

Calculates the reduced bearing capacity of shallow foundations subjected to inclined horizontal shear forces and eccentric bending moments using Meyerhof effective width (B') theory.

How to Use the Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator

  1. Enter your parameters into the designated input fields to calculate the result immediately.

Step-by-Step Example Calculation

Meyerhof Foundation Bearing Capacity with Load Inclination & Eccentricity Calculator Example

Input Values:

footingWidthB:2.5
footingLengthL:3.5
eccentricityEB:0.2
loadInclinationAngleDeg:12
embedmentDepthDf:1.2
soilFrictionAnglePhiDeg:30
soilUnitWeightKnM3:18.5
Worked Steps: Sample evaluation based on standard reference conditions.

Understanding Your Result

The calculated primary figure indicates the optimal or required kPa.

Factors That Affect the Result

  • Measurement tolerances, operational variance, and real-world conditions.

When Should You Use This Calculator?

  • Everyday budgeting, technical homework, professional estimation, and household projects.

Assumptions & Limitations

  • Assumes standard atmospheric or environmental parameters unless specified.

Frequently Asked Questions

Calculation Accuracy & Reference Note

Double-precision IEEE 754 arithmetic with validated empirical constants.

\n

Explore more tools and calculators in Physics Calculators