Electrical Transformer Turns Ratio & Voltage Calculator

Transformers exchange alternating voltage and current through mutual magnetic flux coupling between primary and secondary windings.

Number of wire turns on the primary coil.

Number of wire turns on the secondary coil.

AC supply voltage applied to primary winding.

Connected secondary load impedance in Ohms.

Calculated Result
12 V

Secondary Voltage (V_s)

Secondary Output Voltage (V_s)

12 V

Turns Ratio (a)

10:1 (Step-Down)

Secondary Load Current (I_s)

1.5 A

Primary Input Current (I_p)

0.153 A

Secondary Delivered Power

18 W

Reflected Primary Impedance

800 Ω

Calculation Breakdown

  1. Turns Ratioa = N_p / N_s = 480 / 48 = 10:1
  2. Secondary Output VoltageV_s = V_p / a = 120 / 10 = 12 V
  3. Secondary Load CurrentI_s = V_s / Z_s = 12 / 8 = 1.5 A
  4. Reflected Primary ImpedanceZ_p = a² × Z_s = (10)² × 8 = 800 Ω

Primary vs Secondary Electrical Quantities (10:1 Step-Down)

Interactive visualization based on your current inputs

Value
0.020406080Voltage (V)Current (A)Power (W)Load Z (Ω)Reflected Z (Ω ÷ 10)ParameterValue

What Is the Electrical Transformer Turns Ratio & Voltage Calculator?

An electrical transformer is a static electromagnetic device transferring electrical energy between circuits via mutual inductive coupling.

How Does the Electrical Transformer Turns Ratio & Voltage Calculator Work?

Alternating primary current creates fluctuating magnetic flux in a ferromagnetic core, inducing EMF in the secondary winding by Faraday’s Law.

Electrical Transformer Turns Ratio & Voltage Calculator Formula & Variables

The core mathematical equation utilized by this calculator is expressed as:

a = \frac{N_p}{N_s} = \frac{V_p}{V_s} = \frac{I_s}{I_p}, \quad Z_p = a^2 \cdot Z_s

Turns ratio a sets voltage transformation; secondary current scales inversely; impedance reflects as a squared.

How to Use the Electrical Transformer Turns Ratio & Voltage Calculator

  1. Specify primary and secondary turn counts.
  2. Enter primary AC supply voltage.
  3. Provide secondary load resistance in Ohms.

Step-by-Step Example Calculation

120V to 12V Step-Down Transformer

Input Values:

primaryTurns:480
secondaryTurns:48
primaryVoltage:120.0
secondaryLoadResistanceOhms:8.0
Worked Steps: With a 10:1 ratio, 120V steps down to 12.0V, driving 1.5A (18.0W) into an 8Ω load with reflected primary impedance Zp = 800Ω.

Understanding Your Result

Secondary Voltage (Vs): Transformed output voltage.

Secondary Current (Is): Current delivered to load.

Reflected Impedance (Zp): Apparent load seen by primary supply.

Factors That Affect the Result

  • Turns ratio Np/Ns and core magnetic coupling coefficient.

When Should You Use This Calculator?

  • Power distribution substation design, linear power supply sizing, and audio tube amplifier output impedance matching.

Assumptions & Limitations

  • Assumes high-efficiency laminated iron core operating below magnetic saturation.

Frequently Asked Questions

Calculation Accuracy & Reference Note

Standard AC transformer electromagnetic formulation.

Explore more tools and calculators in Education Calculators